Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Curr Glaucoma Pract ; 12(2): 59-63, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30473600

RESUMO

INTRODUCTION: A continuous method of measuring intraocular pressures (IOP) could be advantageous in the management of glaucoma. This report aims to analyze the potential savings from visit reduction of continuous IOP measurements obtained with an intraocular device. MATERIALS AND METHODS: We constructed a model adapted from a prior study based on the number of glaucoma patients among 5% of the Medicare population. RESULTS: We found that the implementation of a device that continuously measures IOP can result in a reduction of 23.21% in yearly costs from glaucoma outpatient visits. CONCLUSION: Continuous IOP monitoring has the potential to alleviate the economic burden of the current management structure of patients with glaucoma. CLINICAL SIGNIFICANCE: In an era of elevated healthcare costs, continuous IOP monitoring offers an option to improve the care of glaucoma patients through visit reduction, also resulting in a 23.21% reduction in yearly expenses related to glaucoma clinical visits.How to cite this article: Dong J, Syed ZA, Fan K, Yahya AF, Melki SA. Potential Savings from Visit Reduction of Continuous Intraocular Pressure Monitoring. J Curr Glaucoma Pract 2018;12(2):59-63.

3.
Br J Ophthalmol ; 102(10): 1328-1335, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29581352

RESUMO

Tissue adhesives are gaining popularity in ophthalmology, as they could potentially reduce the complications associated with current surgical methods. An ideal tissue adhesive should have superior tensile strength, be non-toxic and anti-inflammatory, improve efficiency and be cost-effective. Both synthetic and biological glues are available. The primary synthetic glues include cyanoacrylate and the recently introduced polyethylene glycol (PEG) derivatives, while most biological glues are composed of fibrin. Cyanoacrylate has a high tensile strength, but rapidly polymerises upon contact with any fluid and has been associated with histotoxicity. Fibrin induces less toxic and inflammatory reactions, and its polymerisation time can be controlled. Tensile strength studies have shown that fibrin is not as strong as cyanoacrylate. While more research is needed, PEG variants currently appear to have the most promise. These glues are non-toxic, strong and time-effective. Through MEDLINE and internet searches, this paper presents a systematic review of the current applications of surgical adhesives to corneal, glaucoma, retinal, cataract and strabismus surgeries. Our review suggests that surgical adhesives have promise to reduce problems in current ophthalmic surgical procedures.


Assuntos
Procedimentos Cirúrgicos Oftalmológicos/métodos , Oftalmologia , Deiscência da Ferida Operatória/prevenção & controle , Adesivos Teciduais/farmacologia , Humanos , Resistência à Tração , Adesivos Teciduais/química
4.
J Refract Surg ; 33(11): 765-767, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29117416

RESUMO

PURPOSE: To assess the accuracy of surgeons' visual estimation of LASIK flap thickness when created by a femtosecond laser by comparing it to ultrasound measurements. METHODS: Surgeons were asked to visually estimate the thickness of a femtosecond flap during the procedure. Total corneal thickness was measured by ultrasound pachymetry prior to the procedure and the stromal bed was similarly measured after flap lifting. The estimates from three experienced surgeons (cornea fellowship trained and more than 5 years in practice) were compared to those of three cornea fellows, with each surgeon evaluating 20 eyes (120 total). Surgeons were not told the thickness of the flaps unless required for safety reasons. RESULTS: The average difference between visual and ultrasonic estimation of LASIK flap thickness was 15.20 µm. The flap was 10 µm thicker than estimated in 37% of eyes, 20 µm thicker in 17% of eyes, and 30 µm thicker in 10% of eyes. The largest deviation was 53 µm. There was no statistically significant difference between the accuracy of experienced surgeons and fellows (P = .51). CONCLUSIONS: There are significant differences between surgeons' visual estimates and ultrasonic measurements of LASIK flap thickness. Relying on these visual estimates may lead to deeper excimer laser ablation than intended. This could lead to thinner residual stromal beds and higher percent tissue altered than planned. The authors recommend that surgeons measure flaps intraoperatively to maximize accuracy and safety. [J Refract Surg. 2017;33(11):765-767.].


Assuntos
Competência Clínica , Substância Própria/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Miopia/cirurgia , Retalhos Cirúrgicos , Ultrassonografia/métodos , Paquimetria Corneana , Substância Própria/diagnóstico por imagem , Feminino , Humanos , Lasers de Excimer/uso terapêutico , Masculino , Miopia/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia de Coerência Óptica , Acuidade Visual
5.
Semin Ophthalmol ; 32(3): 316-320, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27049689

RESUMO

PURPOSE: To identify risks factors for retreatment post-laser in situ keratomeliusis (LASIK). MATERIALS & METHODS: A retrospective chart review from December 2008 to September 2012 identified 1,402 patients (2,581 eyes) that underwent LASIK treatment for myopia with the Intralase™ FS, STAR S4 IR™ Excimer Laser, and WaveScan WaveFront™ technology. In this group, 83 patients were retreated. All charts were reviewed for preoperative age, gender, initial manifest refraction spherical equivalent (MRSE), total astigmatism, and iris registration. RESULTS: Increased incidence rates of retreatment post-LASIK were preoperative age >40 years (p < 0.001), initial MRSE > -3.0 D (p = 0.02), and astigmatism >1D (p = 0.001). Iris registration capture did not significantly reduce the retreatment rate (p = 0.12). CONCLUSIONS: Risk factors for retreatment included preoperative age >40 years, initial MRSE > -3.0 D, and astigmatism >1D. There was no difference in retreatment rate for patients based on gender or iris registration capture.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Refração Ocular/fisiologia , Acuidade Visual , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Retratamento , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
7.
J Cataract Refract Surg ; 42(4): 591-5, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27113883

RESUMO

PURPOSE: To evaluate risk factors leading to loss of epithelial flap integrity in laser-assisted subepithelial keratectomy (LASEK). SETTING: Boston Eye Group, Brookline, Massachusetts, USA. DESIGN: Retrospective case study. METHODS: This retrospective chart review was performed for LASEK surgeries that occurred between January 2009 and October 2013. Logistic regression was performed to determine whether epithelium preservation was correlated with age, sex, sphere, cylinder, spherical equivalent (SE), keratometry, and central corneal thickness (CCT). RESULTS: The study reviewed 1009 eyes of 509 patients with a mean age of 29.1 years ± 12.2 (SD). The mean preoperative spherical refraction was -4.7 ± 2.5 diopters (D), and the mean preoperative cylinder was -1.1 ± 0.8 D. The mean preoperative decimal corrected distance visual acuity was 1.01 ± 0.07. Single-sheet mobilization of the loosened epithelium flap was found in 72.3% of cases. Fragmented preservation events occurred in 17.6% of cases; the flap was discarded in 10.0% of cases. Epithelium preservation was significantly correlated with age (P = .048) but not with other parameters (P > .05 for sex, sphere, cylinder, SE, keratometry, CCT, and surgeon experience). Epithelial flap dissection was less likely to lead to a single epithelial sheet in patients older than 50 years than in younger patients (56.3% versus 74.9%). The mean postoperative decimal uncorrected distance visual acuity (UDVA) at 3 months was 0.98 ± 0.08. There was no statistical difference in postoperative UDVA between the undiscarded flap group and discarded flap group (P = .128). CONCLUSION: Successful dissection of single-sheet epithelial flap diminished with age. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Ceratectomia Subepitelial Assistida por Laser , Miopia/terapia , Adolescente , Adulto , Feminino , Humanos , Lasers de Excimer , Masculino , Refração Ocular , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
8.
Br J Ophthalmol ; 99(11): 1460-5, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25926519

RESUMO

BACKGROUND/AIMS: The goal of this study was to review cataract surgery outcomes at three independent surgery treatment centres established by the UK Specialist Hospitals (UKSH) and to compare these outcomes with recognised benchmarks. METHODS: All patients who underwent cataract surgery at UKSH between July 2005 and March 2013 were included. Complication rates were obtained using annual quality reports, logbooks kept in operating theatres and outpatient departments, and electronic medical records. Refractive outcomes and biometry results between December 2010 and March 2013 were obtained from electronic medical records. Results were compared with previously published benchmarks. RESULTS: This study reviewed 20,070 cataract surgeries. UKSH had lower rates of several operative complications compared with the Cataract National Dataset benchmark study. These included choroidal haemorrhage, hyphaema, intraocular lens complications, iris damage from phacoemulsification, nuclear fragment into the vitreous, phacoemulsification wound burn, posterior capsule rupture or vitreous loss or both, vitreous in anterior chamber, and zonular dialysis. UKSH had lower rates of postoperative complications including corneal decompensation, cystoid macular oedema, iris to wound, posterior capsule opacification with yttrium aluminium garnet indicated, raised intraocular pressure, retained soft lens matter, uveitis, vitreous to section, and wound leak. Biometry outcomes at UKSH were significantly better than recently published benchmarks from the National Healthcare Service. CONCLUSIONS: This is the first large-scale retrospective study of cataract surgery outcomes in the UK independent sector. The results indicate comparable or lower rates for most complications as compared with data collected in a previously published study.


Assuntos
Instituições de Assistência Ambulatorial , Extração de Catarata/normas , Avaliação de Resultados em Cuidados de Saúde , Qualidade da Assistência à Saúde/normas , Acuidade Visual/fisiologia , Idoso , Idoso de 80 Anos ou mais , Benchmarking/normas , Biometria , Feminino , Humanos , Complicações Intraoperatórias , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Medicina Estatal , Tomografia de Coerência Óptica , Reino Unido
9.
Br J Ophthalmol ; 99(9): 1201-5, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25947557

RESUMO

AIM: To characterise the emergence pattern of cavitation bubbles into the anterior chamber (AC) following femtosecond laser-assisted in situ keratomileusis (LASIK)-flap creation METHODS: Retrospective review of patients undergoing femtosecond LASIK surgery at Boston Laser, a private refractive surgery practice in Boston, Massachusetts, between December 2008 and February 2014. Patient charts were reviewed to identify all cases with gas bubble migration into the AC. Surgical videos were examined and the location of bubble entry was recorded separately for right and left eyes. RESULTS: Five thousand one hundred and fifty-eight patients underwent femtosecond LASIK surgery. Air bubble migration into the AC, presumably via the Schlemm's canal and trabecular meshwork, occurred in 1% of cases. Patients with AC bubbles had an average age of 33±8 years with a measured LASIK flap thickness of 96±21 µm. The occurrence of gas bubbles impaired iris registration in 64% of cases. Gas bubbles appeared preferentially in the nasal or inferior quadrants for right (92% of cases) and left (100% of cases) eyes. This bubble emergence pattern is significantly different from that expected with a random distribution (p<0.0001) and did not seem associated with decentration of the femtosecond laser docking system. CONCLUSIONS: The migration of gas bubbles into the AC is a rare occurrence during femtosecond laser flap creation. The preferential emergence of gas bubbles into the nasal and inferior quadrants of the AC may indicate a distinctive anatomy of the nasal Schlemm's canal.


Assuntos
Câmara Anterior/patologia , Enfisema/etiologia , Gases , Complicações Intraoperatórias , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Miopia/cirurgia , Retalhos Cirúrgicos , Adulto , Substância Própria/cirurgia , Feminino , Humanos , Lasers de Excimer/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
10.
Digit J Ophthalmol ; 20(1): 7-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25097457

RESUMO

We present a case of successful completion of a laser in situ keratomileusis (LASIK) procedure despite 5 episodes of suction loss during femtosecond flap creation in a 30-year-old man with no risk factors. The patient had an uncorrected distance visual acuity of 20/20 in both eyes at his 2-month follow-up visit. Our experience in this case shows that multiple suction losses during femtosecond LASIK flap creation do not preclude completion of a successful procedure with excellent visual outcomes. Caution and technique modification are advised if multiple laser passes are applied to avoid creating multiplanar flaps.


Assuntos
Complicações Intraoperatórias , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Sucção , Retalhos Cirúrgicos , Adulto , Humanos , Lasers de Excimer/uso terapêutico , Masculino , Miopia/cirurgia , Resultado do Tratamento
11.
J Cataract Refract Surg ; 40(7): 1224-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24957440

RESUMO

UNLABELLED: We present a case of corneal perforation secondary to an intrastromal astigmatic keratotomy performed with an optical coherence tomography-guided femtosecond laser. The keratotomy was concomitant with cataract surgery and resulted in a flat anterior chamber prior to the start of lens extraction. Interrupted nylon sutures were placed to seal the keratotomy prior to phacoemulsification. Escape of cavitation bubbles into the anterior chamber or the liquid interface can alert the surgeon to the possibility of unintended perforation of the endothelium or the epithelium, respectively. FINANCIAL DISCLOSURE: Neither author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Astigmatismo/cirurgia , Perfuração da Córnea/etiologia , Substância Própria/cirurgia , Ceratotomia Radial/efeitos adversos , Lasers de Excimer/efeitos adversos , Cirurgia Assistida por Computador , Tomografia de Coerência Óptica , Paquimetria Corneana , Feminino , Humanos , Pessoa de Meia-Idade , Facoemulsificação
12.
Br J Ophthalmol ; 98(10): 1315-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24627247

RESUMO

While mean intraocular pressure (IOP) has long been known to correlate with glaucomatous damage, the role of IOP fluctuation is less clearly defined. There is extensive evidence in the literature for and against the value of short-term and long-term IOP fluctuation in the evaluation and prognosis of patients with glaucoma. We present here the arguments made by both sides, as well as a discussion of the pitfalls of prior research and potential directions for future studies. Until a reliable method is developed that allows for constant IOP monitoring, many variables will continue to hinder us from drawing adequate conclusions regarding the significance of IOP variation.


Assuntos
Ritmo Circadiano/fisiologia , Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Progressão da Doença , Humanos , Tonometria Ocular
13.
Cornea ; 33(3): 235-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24457451

RESUMO

PURPOSE: The Boston keratoprosthesis (KPro) is the most commonly used KPro worldwide. There are limited data on the outcomes when irradiated corneas are used as KPro carriers. We report a retrospective analysis of corneal transplantations performed in a regular surgical mission setting in Beirut, Lebanon, using the Boston KPro type 1 and gamma-irradiated carrier corneas, and we describe visual outcomes, complications, and retention percentage. METHODS: We conducted a retrospective analysis of 17 consecutive eyes from 16 patients who underwent Boston KPro type 1 implantation at the Beirut Eye Specialist Hospital between December 2010 and July 2012. Patient medical records were reviewed for preoperative, intraoperative, and postoperative details. RESULTS: Postoperatively, 9 (52.9%), 5 (29.4%), and 2 (11.7%) eyes had a corrected visual acuity of 20/400 or better, 20/100 or better, and 20/40 or better, respectively, at the most recent follow-up visit. A total of 16 eyes (94.1%) improved in corrected visual acuity over the course of follow-up. Overall, 13 eyes (76.4%) developed at least 1 complication after surgery. Retroprosthetic membrane formation was the most common complication, occurring in 10 eyes (58.8%). Neither infectious keratitis nor corneal stromal necrosis was noted during the follow-up period. The retention percentage was 94.1%. CONCLUSIONS: The visual acuity outcomes, incidence of complications, and retention percentage of the KPro using gamma-irradiated carrier corneas are comparable with the outcomes of KPro implantation reported in the literature using fresh grafts as carriers. KPro with irradiated corneal carrier grafts seems to be an effective option to increase the supply of transplantation suitable corneas in remote areas, where fresh corneal grafts may be scarce.


Assuntos
Órgãos Artificiais , Córnea/efeitos da radiação , Doenças da Córnea/cirurgia , Raios gama , Preservação de Órgãos/métodos , Próteses e Implantes , Esterilização/métodos , Adulto , Idoso , Pré-Escolar , Doenças da Córnea/fisiopatologia , Feminino , Sobrevivência de Enxerto/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Implantação de Prótese , Estudos Retrospectivos , Doadores de Tecidos , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
14.
Can J Ophthalmol ; 48(6): 516-20, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24314414

RESUMO

OBJECTIVE: To report the results of a sandwich application of fibrin glue compared with the standard method of using fibrin glue for the attachment of the conjunctival autograft in pterygium surgery. PARTICIPANTS: The study group consisted of 56 consecutive eyes with primary pterygium. METHODS: We performed a retrospective analysis comparing the standard method of using fibrin glue for the attachment of the conjunctival autograft during pterygium excision surgery versus the "sandwich technique." In the "sandwich technique," the thrombin component of the fibrin glue was applied after the graft was secured in position over a bed of fibrinogen. RESULTS: Graft dehiscence occurred in 3 eyes in the conventional group only. Recurrence occurred in 2 eyes in the conventional group and 1 eye in the sandwich group. None of the values reached statistical significance. CONCLUSIONS: The sandwich technique simplifies conjunctival graft fixation during pterygium surgery with conjunctival autograft by allowing more time to properly position the autograft before fibrin clot formation.


Assuntos
Túnica Conjuntiva/transplante , Adesivo Tecidual de Fibrina/uso terapêutico , Pterígio/cirurgia , Adesivos Teciduais/uso terapêutico , Adulto , Idoso , Túnica Conjuntiva/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Oftalmológicos , Complicações Pós-Operatórias , Pterígio/tratamento farmacológico , Estudos Retrospectivos , Transplante Autólogo , Resultado do Tratamento
15.
J Cataract Refract Surg ; 38(7): 1127-9, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22727281

RESUMO

UNLABELLED: We describe the use of a single loose anchoring suture to secure a free flap with good outcomes. We believe this simple, safe technique combines the advantages of previously reported methods, including stability and minimal invasiveness. FINANCIAL DISCLOSURE: Neither author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Substância Própria/cirurgia , Complicações Intraoperatórias , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer/uso terapêutico , Retalhos Cirúrgicos , Técnicas de Sutura , Astigmatismo/cirurgia , Substância Própria/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Miopia/cirurgia , Resultado do Tratamento , Acuidade Visual/fisiologia
16.
J Refract Surg ; 28(1): 74-6, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22074465

RESUMO

PURPOSE: To report the findings and outcomes in two cases in which a contact lens was inadvertently present during creation of a LASIK corneal flap. METHODS: Interventional case report. RESULTS: A soft contact lens blocked the successful creation of the corneal flap with a femtosecond laser in one patient. Repeat surgery 1 week later resulted in a normal flap. In the second patient, a thin but normal-shaped flap was successfully created using a microkeratome despite the presence of a soft contact lens in the patient's eye. No adverse effect on vision was noted in either case. CONCLUSIONS: Refractive surgeons are encouraged to establish or review current procedures to ensure adequate contact lens removal prior to LASIK surgery, as it may result in an aborted procedure or a potentially thin and/or irregular corneal flap.


Assuntos
Lentes de Contato Hidrofílicas , Complicações Intraoperatórias , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Erros Médicos , Retalhos Cirúrgicos , Astigmatismo/cirurgia , Substância Própria/cirurgia , Feminino , Humanos , Hiperopia/cirurgia , Masculino , Pessoa de Meia-Idade , Miopia/cirurgia , Acuidade Visual/fisiologia
17.
Invest Ophthalmol Vis Sci ; 52(13): 9573-80, 2011 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-22039243

RESUMO

PURPOSE: To determine the biocompatibility of a new wireless intraocular pressure (IOP) transducer (WIT) in rabbit eyes and to correlate its measurements with other pressure-measuring devices. METHODS: The WIT is a ring-shaped intraocular device that allows wireless IOP measurements through radiofrequency. It was implanted into six eyes of New Zealand White rabbits after extracapsular lens extraction. A sham rabbit eye with no transducer implanted was used as a control. The animals were observed and examined by microscopy at various intervals up to 25 months after surgery. IOP was measured at various intervals by pneumotonometry, tonometry, WIT, and manometry. The data from the various devices were compared and analyzed for reproducibility. Two eyes were enucleated at 5.5 and 20 months after implantation and analyzed by histology. RESULTS: The WIT appears to be well tolerated in the rabbit eye, with no evidence of significant inflammation or scar formation by microscopic in vivo examination. Histology did not reveal intraocular inflammation or membrane formation. Repeated IOP measurements with pneumotonometry, tonometry, and the WIT resulted in SDs of 2.70 mm Hg, 3.35 mm Hg, and 0.81 mm Hg, respectively. The concordance between the WIT and direct manometry measurements was high. A downward drift in IOP measured by the WIT was noted in three rabbits, necessitating recalibration. CONCLUSIONS: The WIT is well tolerated by the rabbit eye. Its measurements are reproducible and in close concordance with manometry. A downward IOP drift warrants further investigation.


Assuntos
Pressão Intraocular/fisiologia , Ondas de Rádio , Telemetria/instrumentação , Tonometria Ocular/instrumentação , Animais , Teste de Materiais , Coelhos , Reprodutibilidade dos Testes , Transdutores , Transdutores de Pressão
18.
J Cataract Refract Surg ; 37(10): 1748-50, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21930043

RESUMO

UNLABELLED: Laser in situ keratomileusis (LASIK) flap striae can act as a Maddox rod, producing streaks of light perpendicular to the orientation of the striae. This phenomenon can be used in the diagnostic and surgical decision-making process after LASIK. We correlated persistent complaints of starburst by a patient to the presence of LASIK flap striae in both eyes. The more severe striae were subsequently treated with phototherapeutic keratectomy, with complete resolution of symptoms. The LASIK flap striae-induced Maddox rod effect can be used as a simple and useful method with high diagnostic and therapeutic value. FINANCIAL DISCLOSURE: Neither author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Substância Própria/patologia , Técnicas de Diagnóstico Oftalmológico , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Retalhos Cirúrgicos/patologia , Transtornos da Visão/diagnóstico , Feminino , Humanos , Refração Ocular/fisiologia , Transtornos da Visão/etiologia , Acuidade Visual/fisiologia , Adulto Jovem
19.
Can J Ophthalmol ; 46(4): 319-21, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21816250

RESUMO

Centration of multifocal Intraocular lenses (IOL) may be critical to ensure optimal function and prevent untoward side effects. Pharmacologic pupillary dilation and constriction may shift the physiologic location of the pupillary center rendering intraoperative positioning of multifocal IOL challenging. Similarly, the anterior capsular center is difficult to pinpoint and may not correspond to either the visual axis or the pupillary center. The visual axis is the only landmark that can be consistently identified prior, during and after cataract surgery. Centering diffractive multifocal IOL on the visual axis may allow more consistent placement and better outcome measures. In the following, we describe a simple technique to center multifocal single piece acrylic IOLs on the visual axis.


Assuntos
Implante de Lente Intraocular/métodos , Lentes Intraoculares , Luz , Extração de Catarata/métodos , Humanos , Reflexo/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...